6.8.34. Injection configuration — fuel rail pressure compensation (pan_InjectorCompConfig_DI)

Configure the volume to duration conversion for direct injection.

6.8.34.1. Supported targets

M220-000, M221-000, M250-000 and M670-000

6.8.34.2. Required license

None (Main library). (See Section 2.3, “Licensed Features”.)

6.8.34.3. Description

The pan_InjectorCompConfig_DI block configures the fuel rail pressure (FRP) analogue input used to convert injection volume requests into units of time. As described in Section 6.5.2, “Direct injection” just prior to each direct injection pulse is made, the fuel rail pressure analogue input is sampled. Any volume request is converted to a duration using a 2D lookup map. This technique compensates for rapid variation in the fuel rail pressure that may occur after the injection schedule is requested by the application.

6.8.34.4. Inports

None.

6.8.34.5. Outports

None.

6.8.34.6. Mask parameters

  • Channel

    A drop-down selection of analogue input channels to use as the fuel rail pressure input.

    Value type:List
    Calibratable:No
  • Fuel rail pressure transfer function - volts axis

    This is the X-axis of the transfer function that converts the fuel rail pressure sensor voltage into engineering units of MegaPascals (MPa). The voltages contained within this axis should range between zero and the voltage specified with the Fuel rail pressure maximum voltage parameter.

    Size: [2, 10] elements, for M220, M221 and M250 targets Size: [2, 15] elements, for M670 targets Range: [0, Fuel rail pressure maximum voltage] volts

    Value type:Real
    Calibratable:Yes, offline
  • Fuel rail pressure transfer function - pressure

    This is the Z-data of the transfer function that converts the fuel rail pressure sensor voltage into engineering units of MegaPascals (MPa).

    Size: 1 by [2, 10] elements, for M220, M221 and M250 targets Size: 1 by [2, 15] elements, for M670 targets Range: [0, 500] MPa

    Value type:Real
    Calibratable:Yes, offline
  • Fuel rail pressure maximum voltage

    This is the maximum voltage that can be read by the chosen analogue input Channel before the input saturates, e.g., will be 5.0 on a 0-5v input. This allows the ECU to convert a raw number of A/D converter counts into a voltage.

    Range: [0, 24] volts

    Value type:Real
    Calibratable:Yes, offline
  • Injector characteristic map - fuel volume axis

    This is the X-axis of the injection duration map.

    Size: [2, 10] elements, for M220, M221 and M250 targets Size: [2, 15] elements, for M670 targets Range: [0, 512] mm3

    Value type:Real
    Calibratable:Yes, offline
  • Injector characteristic map - fuel rail pressure axis

    This is the Y-axis of the injection duration map.

    Size: [2, 10] elements, for M220, M221 and M250 targets Size: [2, 15] elements, for M670 targets Range: [0, 500] MPa

    Value type:Real
    Calibratable:Yes, offline
  • Injector Characteristic map - injection duration

    This is the data of the injection duration map (Z-data default), the actual injection durations.

    Size: [2, 10] by [2, 10] elements, for M220, M221 and M250 targets Size: [2, 15] by [2, 15] elements, for M670 targets Range: [0, 1000] milliseconds Resolution: (floor(max_duration/16.38375ms)+1)*0.2500us for M220, M221 and M250 targets Resolution: (floor(max_duration/15.88727ms)+1)*0.2424us for M670 target

    Value type:Real
    Calibratable:Yes, offline

6.8.34.7. Notes