7.7.55. J1939 update NTE status (pj1939_UpdateNteStatus)

Provide the facility to update the NTE status (as reported in J1939 message DM34).

7.7.55.1. Supported targets

All targets

7.7.55.2. Required license

EXT_DIAG (Extended diagnostics library). (See Section 2.3, “Licensed Features”.)

7.7.55.3. Description

The platform requires information regarding the status of the engine operation in the NTE control areas, for given pollutants such as NOx and PM. This block provides the facility to update that information in order that a J1939 DM34 message (when requested) contains up-to-date data. Refer to J1939-73 FEB2010 section 5.7.34 for details of the various NTE areas.

7.7.55.4. Inports

  • nte_status

    A 2-bit status code indicating the status of engine operation within the manufacturer specific NTE area. See J1939-73 FEB2010 section 5.7.34 for details of these codes.

    Value type:Integer
    Calibratable:No

7.7.55.5. Outports

None.

7.7.55.6. Mask parameters

  • NTE area

    A drop down to identify the NTE area for which the status is to be updated.

    Value type:List
    Calibratable:No
  • Sample time

    The periodicity of the block execution.

    Range: [0.001, 3600] seconds

    Value type:Real
    Calibratable:No

7.7.55.7. Notes

This block updates the platform data for the pj1939_dm34Transmit block.