== My calibration map / table is not working == By far, the most common reason for this issue is that the variable names do not follow the required naming convention. Map / Table calibration variables must adhere to the following naming convention: * The 4th character '''must''' be 'm' * All variables associated with the table must have the same name, except for the last two characters * The last two characters of the variable name must be '_x' for the input x-axis, '_y' for the input y-axis (2-D maps only), and '_z' for the output axis. ==== Example: 1-D map ==== Assume you are trying to map voltage to temperature using a 1-D table. Your x-axis (input axis) will be in units of volts, while your z-axis (output axis) will be in units of degrees C. Then your map variables could be as follows: * x-axis (1-D vector): INPm_volts2degc_x * z-axis (1-D vector): INPm_volts2degc_z ==== Example: 2-D map ==== Assume you are trying to create a spark advance map using mass airflow and RPM as your inputs. Your x-axis (input axis) will be in units of grams of air, your y-axis (input axis) will be in units of RPM, and your z-axis (output axis) will be in units of degrees before TDC. Then your map variables could be as follows: * x-axis (1-D vector): SPKm_sparkMap_x * y-axis (1-D vector): SPKm_sparkMap_y * z-axis (2-D matrix): SPKm_sparkMap_z ---- [[OpenECU Support Contact|This did not solve my problem]]